Class a chimney usually has a 2 inch clearance to combustibles and a type b gas vent normally has 1 inch clearance.
Gas fireplace pipe clearance.
Gas fireplaces are another popular heating option.
Menards offers a variety of fireplaces including indoor wood fireplaces.
This is the method commonly used for sidewall venting.
Menards also offers the venting and accessories you need to install your stove or fireplace.
Clearance above paved sidewalk or a paved driveway located on public property.
Distance required usa 2.
Zero clearance direct vent gas fireplace figure 1.
Direct vent gas fireplace exhaust termination item clearance distance.
Double wall stovepipe is used when you don t have 18 or more clearance from combustibles.
Minimum clearance distance requirements for the exterior vent termination of a gas fireplace heater 8.
84 2 1m 3 note 5.
For a gas fireplace exhaust termination cap 3 feet 91cm above if within 10 feet 3m horizontally.
And the inner pipe exhausts the combustion products.
We have a variety of reliable pipe options including insulated double wall stove pipe black stove pipe pellet stove pipe and wood fireplace venting.
Distance required canada 1.
Superior compact termination kit with sv4 5 direct vent pipe drt2035 fireplaces superior securevent horizontal termination small square sv4 5htss dura vent directvent pro 5 inch inner diameter adjustable galvanized vent pipe 17 inch to 24 inch length.
Pleasant hearth 45 88 in tobacco ventless natural or liquid propane gas fireplace.
Collinear venting uses two.
It typically has a 1 inch clearance when it is run vertically but when it is run horizontally the clearance requirements vary.
Most of the double wall stove pipe allows for 6 clearance from wall combustibles and 8 from ceiling combustibles.
The nfpa calls for an 18 clearance to combustible walls for single wall stove pipe.
For a gas fireplace exhaust termination cap 3 feet 91cm within a height of 15 feet 4 5m above the meter regulator assembly.
For pricing and availability.
In addition if the side panels of your mantel project more than 1 1 2 inches from the fireplace facing you will need additional clearance equal to this projection.
Vent pipe for a direct gas fireplace is unique.
All combustible mantel surrounds and shelves must be kept at least 12 inches from the opening of your fireplace top and sides.
Gas fireplace insert in existing wood burning fireplace outside wall sidewall vent chimney liner existing fireplace cavity gas.
Pleasant hearth 45 88 in heritage ventless natural gas fireplace.